Single/Dual Channel Vehicle Loop Detector

Model:LD-100
——————————————————————
Technology Parameter
01 :LINE ,(AC100V-AC240V)
02 :NEUTRAL,(AC100V-AC240V)
03 :N.O.of Relay B
04 :COM.of Relay B
05 :N.O.of Relay A
06 :COM.of Relay A
07 :LOOP
08 :LOOP
09 :Ground
10 :N.C.of Relay A
11 :N.C.of Relay B
Function And Advantage Introduction 
Wide range of detection:
The detecting range can be from 15UH-2000UH, the loop detector can be in stable work status no matter the inductive value how to changes.
Many type vehicles can be detected:
It can detect many type vehicles with different height and weight, like Motorcycle, Truck, Car, Bus, etc.
Adapt to the bad environment:
All of our loop detector we do temperature test and corrosion test(-40 degree to 70 degree), let it always keep the outstanding performance.
Installation Diagram And Application
Size

Model:LD-102
——————————————————————
Technology Parameter
01 :+(12-24VADC) 
02 :-(12-24VADC)
03 :N.O.of Relay B
04 :COM.of Relay B
05 :N.O.of Relay A
06 :COM.of Relay A
07 :LOOP
08 :LOOP
09 :Ground
10 :N.C.of Relay A
11 :N.C.of Relay B
Function And Advantage Introduction 
Wide range of detection:
The detecting range can be from 15UH-2000UH, the loop detector can be in stable work status no matter the inductive value how to changes.
Many type vehicles can be detected:
It can detect many type vehicles with different height and weight, like Motorcycle, Truck, Car, Bus, etc.
Adapt to the bad environment:
All of our loop detector we do temperature test and corrosion test(-40 degree to 70 degree), let it always keep the outstanding performance.

Installation Diagram And Application
Size

Model:LD-200
——————————————————————
Technology Parameter
01 :LINE,(AC100V-AC240V)
02 :NEUTRAL,(AC100V-AC240V)
03 :CH1 LOOP
04 :CH1 LOOP
05 :CH2 LOOP
06 :CH2 LOOP
07 :CH2 Relay COM
08 :CH2 Relay N.O
09 :Ground
10 :CH1 Relay COM
11 :CH1 Relay N.O
Function And Advantage Introduction 
Wide range of detection:
The detecting range can be from 15UH-2000UH, the loop detector can be in stable work status no matter the inductive value how to changes.
Many type vehicles can be detected:
It can detect many type vehicles with different height and weight, like Motorcycle, Truck, Car, Bus, etc.
Adapt to the bad environment:
All of our loop detector we do temperature test and corrosion test(-40 degree to 70 degree), let it always keep the outstanding performance.

Installation Diagram And Application
Size

Model:LD-202
——————————————————————
Technology Parameter
01 :+(12-24VADC)
02 :-(12-24VADC)
03 :CH1 LOOP
04 :CH1 LOOP
05 :CH2 LOOP
06 :CH2 LOOP
07 :CH2 Relay COM
08 :CH2 Relay N.O
09 :Ground
10 :CH1 Relay COM
11 : CH1 Relay N.O

Function And Advantage Introduction 
Wide range of detection:
The detecting range can be from 15UH-2000UH, the loop detector can be in stable work status no matter the inductive value how to changes.
Many type vehicles can be detected:
It can detect many type vehicles with different height and weight, like Motorcycle, Truck, Car, Bus, etc.
Adapt to the bad environment:
All of our loop detector we do temperature test and corrosion test(-40 degree to 70 degree), let it always keep the outstanding performance.

Installation Diagram And Application
Size

评论

此博客中的热门博文

180° rotational photocell beam sensors

Parking Management System

How to choose and install Gate Automation Photocell